Solar sales material is full of production claims with no method behind them. Here is the method, the numbers it produces for every kit size we sell, and the four reasons a real array underperforms the calculation.

The formula

Daily kWh = system size (kW) × peak sun hours × 0.8

Peak sun hours are not daylight hours. They are the equivalent number of hours at 1,000 W/m² of irradiance. Most of the US gets between 4 and 5.5 a year on average; Phoenix reaches 6.5, Seattle about 3.5. The 0.8 is the derate factor — a realistic allowance for heat, wiring, inverter conversion and soiling.

Multiply the daily figure by 365 for the annual total. Multiply by 30 for a rough monthly figure, remembering that real months vary far more than 30 versus 31 days.

Daily and annual output by system size

Daily kWh at different average peak sun hours, after a 0.8 derate. Annual column assumes 5 peak sun hours, i.e. 1,460 kWh per installed kW.
System4.0 PSH4.5 PSH5.0 PSH5.5 PSH6.5 PSHPer year
3kW9.610.812.013.215.64,380 kWh
5kW16.018.020.022.026.07,300 kWh
7kW22.425.228.030.836.410,220 kWh
8kW25.628.832.035.241.611,680 kWh
10kW32.036.040.044.052.014,600 kWh
12kW38.443.248.052.862.417,520 kWh
15kW48.054.060.066.078.021,900 kWh
20kW64.072.080.088.0104.029,200 kWh

For context, the average US household uses about 10,500 kWh a year, or 29 kWh a day. An 8kW kit at five peak sun hours produces 32 kWh a day — a little more than the average home needs, which is exactly why 7–8kW is the most common residential size in the country.

Production is not flat across the year

An annual total is an average of twelve very different months. For an 8kW array in Austin:

Illustrative monthly output for an 8kW array at 1,460 kWh per kW per year. Cloud patterns shift these figures by 10–15% year to year.
MonthDaily kWhMonthly kWhShare of annual
January226825.8%
April341,0208.7%
June381,1409.8%
August361,1169.6%
October298997.7%
December216515.6%

June produces roughly 1.8 times what December does. In Seattle the ratio is closer to 4:1. This matters for two things: your winter bill, and off-grid sizing, which has to be built around the worst month rather than the average. See system types for why off-grid needs a different method entirely.

Why your real output will be lower

Typical losses for a well-installed residential array. The 0.8 derate already bundles these; this table shows what is inside it.
LossTypical rangeNotes
Temperature5–12%Panels lose about 0.35% of output per °C above 25°C. Roof-mounted arrays run hot.
Soiling2–5%Dust, pollen and bird droppings. Higher in dry regions; rain helps.
Inverter conversion2–4%Modern string and hybrid inverters are 96–98% efficient.
Wiring and connectors1–2%Long DC runs and undersized cable cost more.
Shade0–25%The only loss that can be partly recovered, with panel-level electronics.
Clipping0–2%An inverter slightly smaller than the array is normal and efficient.

The fastest way to see whether a system is performing: compare its output on a clear day with the table above. An 8kW array making 20 kWh on a bright June day in Texas has a problem — a shaded string, a tripped breaker, or a monitoring fault. Persistent underperformance is usually soiling or shade, not a failed panel.

What that production is worth

Multiply annual kWh by your rate. At $0.17/kWh an 8kW system producing 11,680 kWh is worth about $1,986 a year if every kilowatt offsets a kilowatt you would otherwise buy. It will not, because some production lands when the house is not using it.

  • Net metering at retail. Exported kWh are credited at the full rate. The simple calculation holds.
  • Net billing at avoided cost. Exports earn a lower rate, so the same array is worth less unless you add a battery or shift load.
  • No export compensation. Everything not used on site is worth nothing, and the array should be sized to daytime load, not annual total.

This is why two identical systems in two states can have a four-year difference in payback. Net metering versus net billing explains how to find out which applies to you before you size anything.

Production and battery capacity are different numbers

A battery is sized in kWh of storage, and only 90–95% of that is usable. A 13.5kWh battery gives you roughly 12.5kWh of delivered energy — about half a summer day of production from an 8kW array, and enough for most homes from sunset to sunrise.

The practical rule: match battery kWh to your evening and overnight consumption, not to your daily production. If the array makes 32 kWh and the house uses 20 of them after dark, a 13.5kWh battery covers the bulk of it. Read the Pylontech battery page for how modules stack.

How to check a production estimate you are given

  1. Ask for the annual kWh figure, not just "savings".
  2. Divide by the system kW. If the answer is above about 1,800 kWh per kW, the estimate is optimistic unless you live in the desert southwest.
  3. Ask what derate factor was used. Anything above 0.85 is unrealistic for a roof-mounted system.
  4. Compare with our table above and with a public tool such as NREL's PVWatts, which uses your address and tilt.

Our calculator uses 1,400 kWh per kW per year as a middle default and lets you change it. If a quote claims 20,000 kWh a year from an 8kW array in Ohio, it is 70% too high.

Which kit produces what

Every kit page states its annual production at 1,400 kWh per kW. That is a deliberately conservative national middle. In Phoenix you will beat it; in Seattle you will not.

If you know your annual kWh, the sizing guide turns it into a system size in one step. If you want to compare the equipment itself rather than the output, the full comparison table has every spec in one view.

Questions we get about this

How many kWh does a 5kW solar system produce per day?

Between about 16 and 26 kWh a day depending on location, using kW × sun hours × 0.8 for real-world losses. At the US average of five peak sun hours that is 20 kWh a day, or roughly 7,300 kWh a year.

Does a 10kW system really produce 40 kWh a day?

On a clear average day at five peak sun hours, yes — about 40 kWh. In December in the northern half of the country it can be half that, and in Phoenix in June it can exceed 50 kWh. The annual total is the number that matters for payback.

Why does my system produce less than the formula says?

Heat, soiling, shade, inverter clipping and wiring losses all take a bite. Soiling alone costs 2–5% in most of the country and more after a dusty summer. A dirty array with one shaded string can lose 20%.

How much does a solar system produce in winter?

Roughly 40–60% of the summer daily figure in northern states, and 60–75% in the Sun Belt. December is usually the worst month; June or July is the best. Annual totals smooth this out but monthly bills do not.

Is production measured in kW or kWh?

kW is capacity — the size of the array. kWh is energy actually produced over time. A 10kW system is always 10kW; it produces a different number of kWh every single day.

Want the numbers for your house?

Send three months of electric bills and a roof photo. A designer confirms the array size, the kit and the delivered price — usually within two business hours.

Get a free system review
Keep reading

Related guides

Not sure which kit matches your number?

Tell us your monthly kWh and state. We will name the smallest kit that covers it — and say so plainly if none of ours is the right fit.